Sinny Global Website
China / Chinese
Vietnam / Vietnamese
Global / English
USA / English
Brazil / Portuguese
Mexico / Spanish
Colombia / Spanish
Peru / Spanish
Chile / Spanish
Venezuela / Spanish
Ecuador / Spanish
Global / English
Turkey / Turkish
United Kingdom / English
Spain / Spanish
Portugal / Portuguese
Global / English
Arab / Arabic
Global / English
Temperature Controller
Temperature and Humidity Controller
Solid State Relay
TC5 Temperature Controller Has 100ms High-Speed Sampling Period And +0.5% Display Accuracy, 100-240v Wide Voltage , While Supporting A Variety Of Thermocouple / Rtd / Analog Signal Input, Output Can Be Freely Switched Relay / SSR, And Can Be Customized Analog Output To Meet Different Working Conditions.
· Diameter depth 75mm
· HD white light display
· Thermocouple / RTD / Analog input switch function available
· Fahrenheit / Celsius unit switch function available
· RS485 communication output model: communication protocol Modbus RTU
· Switch between Relay output and SSR drive output
· Enhanced PID+ control algorithm
· Automatic calculation function
· Display error correction function
· Heating/cooling mode selectable
· 12 alarm modes selectable
HD LED display
Diameter depth 75mm
Various Inputs
Temperature unit switch
Relay / SSR output switch
Various output model
RS485 communication model
PID+ control
Auto tuning
Display error correction
Heating/cooling mode select
12 alarm modes select
Bright
All support
Global adaptation
Flexible
Provide a variety of solutions
Communication protocol Modbus RTU
Stable control
Meet the requirements of different working conditions
Quick switching by shortcut keys:
In the operation mode
Press and hold the "↓" and "↑" keys simultaneously for 3 seconds.
Please operate as follows:
1. Hold the "SET" key for 2s,The [P-1] page appears, press the "↑" key once, and the [P-2] page appears.
2. In [P-2], press the "SET" key once, the input specification [INP] page appears, adjust it with the "↑" and "↓" keys.
After adjusting, hold the "SET" key for 3s to save the parameter and return to run mode.
Check the following conditions:
1. whether the input sensor is damaged
2. whether the input wiring is correct
3. Whether the input type of the controller [INP] is matched with the sensor
4. Whether the error correction [EC] parameter is set correctly
5. Whether the parameters of the lower range limit [SLL] and upper range limit [SLH] are set correctly.
Address:8 Changsheng Road, Liushi Town, Yueqing City, Wenzhou City, Zhejiang Province
Email: sinny@sinny.com
Sales Hotline: +86-577-82238888